ELB Electronics LED T8 U-Bend and 8’ direct replacement lamps, requiring NO Re-WIRING of the light fixture, provide excellent energy savings when replacing T8 and T12 fluorescent lamps. Installation is easy…just remove existing fluorescent lamps and install the LED linear lamp.
Multi-OpTM (multi-Operation) LED lamp design works with multiple input sources including T8 Electronic Instant Start, T8 Program Start and T12 Magnetic ballasts.
|
The company's LED T8 tubes with 6”, 3” and 1-5/8” width extensions. (ELB Electronics/LEDinside)
|
|
The Multi-OpTM LED product is the most versatile LED linear lamp on the market today. The LED Multi-OpTM liner lamp is also compatible with most existing fluorescent emergency ballasts.
If the existing ballast fails just replace the ballast or operate the LED lamp with the optional 120-277VAC LED remote driver.
Benefits:
-
Easy to carry, store and ships easily
-
Excellent for low temperature applications
-
Use with occupancy sensors with frequent starting
-
Instant ON operation - No flickering
-
Dimmable
-
No glass or mercury for safer work environments
-
Less lumen deprecation compared to fluorescent systems
-
Meets UL standard 1598c
-
Long life product (>55,000 hours)
-
5 Year manufacturer’s warranty
Energy Savings over 40-50% when compared to existing fluorescent T8 and T12 electronic and magnetic ballasted fixture applications.
For additional energy savings of 20-30% use with low ballast factor ballast or lighting control system.
Installation is easy and saves money. Just change the existing lamps without the need to re-wire the light fixture. Install LED lamp using existing fluorescent ballast. If the ballast fails, LED lamp can operate using optional 120-277VAC LED driver.
LED direct replacement models available
for 2’, 4’, U-Bend and 8’ fluorescent replacement.
|
INNOVATIVE two piece designs provide easy handling and transporting. Lamp snaps together in seconds.
|
Specifications:
Performance with various ballast types:
Model #
|
Type
|
T8 IS Electronic ballast
|
T8 Program Start Electronic ballast
|
T12 Magnetic ballast
|
Lumens
|
Average System Watts
|
Lumens
|
Average System Watts
|
Lumens
|
Average System Watts
|
4’ U-Bend lamp
|
|
|
|
|
|
|
|
LEDT8-17U-850-B-xxx
|
LED T8
|
1650
|
16.45
|
1650
|
17.0
|
2100
|
28.0
|
LEDT8-17U-840-B-xxx
|
LED T8
|
1600
|
16.45
|
1600
|
17.0
|
2000
|
28.0
|
LEDT8-17U-835-B-xxx
|
LED T8
|
1500
|
16.45
|
1500
|
17.0
|
1950
|
28.0
|
LEDT8-17U-830-B-xxx
|
LED T8
|
1500
|
16.45
|
1500
|
17.0
|
1900
|
28.0
|
8’ linear lamp
|
|
|
|
|
|
|
|
LEDT8-44-850-B-xxx
|
LED T8
|
3800
|
40.2
|
|
|
|
|
LEDT8-44-840-B-xxx
|
LED T8
|
3700
|
40.2
|
|
|
|
|
LEDT8-44-835-B-xxx
|
LED T8
|
3500
|
40.2
|
|
|
|
|
LEDT8-44-830-B-xxx
|
LED T8
|
3500
|
40.2
|
|
|
|
|
Note: All specification Information subject to change without notice
U-Bend size extensions: (Order with tube sections)
LEDT8-U6
|
Extension to support 6” U-bend width
|
LEDT8-U3
|
Extension to support 3” U-bend width
|
LEDT8-U1-5/8
|
Extension to make 1-5/8” U-bend width
|
LED T8 Performance with different ballast factor Instant Start (IS) ballasts
|
T8 IS Low
Ballast Factor (0.78)
|
T8 IS Normal Ballast Factor (0.88)
|
T8 IS High
Ballast Factor (1.18)
|
|
Lumens
|
Lamp Watts
|
Lumens
|
Lamp Watts
|
Lumens
|
Lamp Watts
|
LEDT8-17U-850-B-xxx
|
1450
|
14.50
|
1650
|
16.50
|
2100
|
22
|
LEDT8-17U-840-B-xxx
|
1400
|
14.50
|
1600
|
16.50
|
2000
|
22
|
LEDT8-17U-835-B-xxx
|
1300
|
14.50
|
1500
|
16.50
|
1900
|
22
|
LEDT8-17U-830-B-xxx
|
1300
|
14.50
|
1500
|
16.50
|
1900
|
22
|
Step 2: Remove Fluorescent lamp
|
Step 3: Plug in Quick-Fit LED lamp
|
Installation Instructions: Quick and Simple - No re-wiring required
|
Program Start Electronic T8 or Magnetic T12 Rapid Start Ballast
|
Existing Ballast Wiring Options:
OPTIONAL: Remote AC LED Driver
(Standard or Diming model)
|